Errors
Member Cardiovascular::CalculateVitalSigns ()

Fatal: Diastolic pressure has fallen below -2

Fatal: Systolic pressure has exceeded 700

Member Cardiovascular::ChronicAnemia ()
if too much hemoglobin is removed, we will no longer meet validation, so set to maximum amount that can be removed.
Member Cardiovascular::ChronicPericardialEffusion ()

Cannot specify volume accumulation greater than 1000 mL. Accumulated volume is now set at 1000 mL.

Cannot specify volume accumulation less than 0 mL. Accumulated volume is now set at 0 mL.

Member Cardiovascular::ChronicRenalStenosis ()

Cannot specify left occlusion fraction less than zero

Cannot specify right occlusion fraction less than zero

Cannot specify left occlusion fraction greater than one

Cannot specify right occlusion fraction greater than one

Member Cardiovascular::CPR ()
Warning: CPR compression ratio must be a positive value between 0 and 1 inclusive.
Member Cardiovascular::Hemorrhage ()

Error: Bleeding rate cannot be less than zero

Error: Bleeding must be from a vascular compartment

Fatal: Bleeding must come from nodes in the circultatory circuit

Error: Hemorrhage compartments must have nodes in the circulatory circuit

Member Cardiovascular::PericardialEffusion ()

Effusion rate is out of physiologic bounds. Effusion rate is reset to 1.0 milliliters per second.

Cannot specify effusion rate less than zero. Effusion rate is now set to 0.0.

Member Drugs::AdministerSubstanceBolus ()
Error: Unavailable Administration Route
Member Drugs::AdministerSubstanceCompoundInfusion ()
Fatal: rate cannot exceed 285 mL/min
Member Drugs::AdministerSubstanceInfusion ()
Fatal: Titration administration cannot be negative
Member Drugs::CalculatePartitionCoefficients ()
Fatal: Binding Protein not supported
Member Environment::ProcessActions ()

Warning: SurfaceArea and SurfaceAreaFraction are both set. The largest fraction will be used.

Warning: Neither SurfaceArea nor SurfaceAreaFraction are set. A fraction of 1 will be used.

Warning: Thermal application effective area exceeds the total skin surface area. A fraction of 1 will be used.

Warning: SurfaceArea and SurfaceAreaFraction are both set. The largest fraction will be used.

Warning: Neither SurfaceArea nor SurfaceAreaFraction are set. A fraction of 1 will be used.

Warning: Thermal application effective area exceeds the total skin surface area. A fraction of 1 will be used.

Warning: AppliedSurfaceArea and AppliedSurfaceAreaFraction are both set. The largest fraction will be used.

Warning: Neither AppliedSurfaceArea nor AppliedSurfaceAreaFraction are set. A fraction of 1 will be used.

Warning: Thermal application effective area exceeds the total skin surface area. A fraction of 1 will be used.

Member Environment::StateChange ()
Fatal: Total ambient/environment gas volume fractions must sum to 1.0.
Member Gastrointestinal::PreProcess ()
Unable to read consume meal action file
Member Inhaler::Administer ()

: Already processing a Substance Inhalation, ignoring this command.

Fatal: Inhaled substance does not have a density value.

Member MechanicalVentilator::CalculateExpiration ()

Fatal: Inspiration flow trigger is not yet supported.

Fatal: No inspiration trigger defined.

Fatal: Functional residual capacity expiratory baseline not yet supported.

Fatal: Non-square waveforms are not yet supported.

Member MechanicalVentilator::CalculateInspiration ()

Fatal: Expiration pressure cycle is not yet supported.

Fatal: Expiration flow cycle is not yet supported.

Fatal: No expiration cycle defined.

Fatal: Limits are not yet supported.

Fatal: Inspiration mode not yet supported.

Fatal: Non-square waveforms are not yet supported.

Member MechanicalVentilator::SetVentilatorDriver ()

Error: Ventilator driver pressure and flow both set, only one allowed. Using the pressure value.

Error: Ventilator driver pressure or flow must be set. Using a pressure of 0.

Member MechanicalVentilator::StateChange ()
Error: FiO2 setting + ambient fractions other than N2 is greater than 1.0. Setting FiO2 to max value
Member Renal::CalculateActiveTransport ()
Fatal: Unrecognized renal clearance type
Member Respiratory::Pneumothorax ()

Patient: Cannot perform an intervention if Tension Pneumothorax is not present on that side.

Patient: Cannot perform an intervention if Tension Pneumothorax is not present on that side.

Patient: can't process needle decompression if no pneumothorax is present

Patient: can't process a chest occlusive dressing if no pneumothorax is present

Member Respiratory::SetRespiratoryResistance ()
Error: Ignoring the resistance override. The airway resistance cannot be lowered enough to meet the criteria.
Member Respiratory::UpdateDiffusion ()

Fatal: The Impaired Alveolar Exchange action must include a surface area, fraction, or severity.

Warning: The Impaired Alveolar Exchange action is defined with mulitple values. Defaulting to the surface area value first, impaired fraction next, and severity last.

Fatal: The Impaired Alveolar Exchange action must include a surface area, fraction, or severity.

Warning: The Impaired Alveolar Exchange condition is defined with mulitple values. Defaulting to the surface area value first, impaired fraction next, and severity last.

Member SECircuit< CIRCUIT_TEMPLATE >::StateChange ()

Fatal: Invalid Path in the Circuit.

Fatal: There are too many assumed state options. The Circuit solver can only handle up to 64 Diodes and Polar Elements in a single circuit (i.e. ~1.8e19 possible combinations).

Member SECircuitCalculator< CIRCUIT_CALCULATOR_TEMPLATE >::CheckAndModifyValves ()
Fatal: The combination of valves precludes the circuit from being solved.
Member SECircuitCalculator< CIRCUIT_CALCULATOR_TEMPLATE >::ParseIn ()

Fatal: Circuit must have at least 1 reference node

Warning: Reference pressure is not defined - setting it to 0.

Fatal: Multiple Reference Potentials must be equal

Fatal: Resistance cannot be negative

Warning: Initial compliance source pressure is not defined, assuming it is the reference pressure.

Warning: Initial compliance target pressure is not defined, assuming it is the reference pressure.

Fatal: Capacitance cannot be negative

Warning: Initial inductance is not defined, assuming it is 0.

Warning: Initial inductance source pressure is not defined, assuming it is the reference pressure.

Warning: Initial inductance target pressure is not defined, assuming it is the reference pressure.

Fatal: Inductance cannot be negative

Member SECircuitCalculator< CIRCUIT_CALCULATOR_TEMPLATE >::Solve ()
Fatal: The solver was unable to determine a solution for the circuit.
Member SEConditionManager::Copy (const SECondition &condition, const SESubstanceManager &)
Unsupported Condition
Member SEEnvironment::ProcessChange (SEInitialEnvironmentalConditions &change, SESubstanceManager &subMgr)
Unable to read Configuration Action file
Member SEEnvironment::ProcessChange (SEChangeEnvironmentalConditions &action, SESubstanceManager &subMgr)
Unable to read Configuration Action file
Member SEEnvironmentActionCollection::ProcessAction (const SEEnvironmentAction &action, SESubstanceManager &)
Unsupported Action
Member SEEquipmentActionCollection::ProcessAction (const SEEquipmentAction &action, SESubstanceManager &)
Unsupported Action
Member SEPatientActionCollection::ProcessAction (const SEPatientAction &action, SESubstanceManager &)

Unknown ChestCompression type

Unsupported Action

Member SESubstanceTransporter< SUBSTANCE_TRANSPORTER_TEMPLATE >::Transport (GraphType &graph, double timeStep_s)

Fatal: Can't transport with a negative quantity included.

Fatal: Can't transport with a negative volume included.