AnesthesiaMachineData
Amount of oxygen in the bottle. More...
Modules | |
| Connection | |
| eSwitchTable | |
| InletFlow | |
| The total fresh gas inlet flow. | |
| InspiratoryExpiratoryRatio | |
| The ratio of time spent in the inspiratory phase vs the expiratory phase of respiration. | |
| OxygenFraction | |
| The fraction of the fresh gas inlet flow that is oxygen. | |
| OxygenSource | |
| AnesthesiaMachineData_eOxygenSourceTable | |
| PeakInspiratoryPressure | |
| The peak pressure of the ventilator. | |
| PositiveEndExpiratoryPressure | |
| The pressure above atmospheric pressure that exists in the lungs at the end of expiration. | |
| PrimaryGas | |
| AnesthesiaMachineData_ePrimaryGasTable | |
| ReliefValvePressure | |
| Pressure at while the valve opens to prevent a build up of pressure in the system. | |
| RespiratoryRate | |
| The prescribed rate of positive-pressure ventilation. | |
| LeftChamber | |
| The left chamber of the machine. | |
| RightChamber | |
| The right chamber of the machine. | |
| OxygenBottleOne | |
| The first bottle attached to the machine. | |
| OxygenBottleTwo | |
| The second bottle attached to the machine. | |
| Common | |
| Inhaling | |
| CurrentBreathingCycleTime_s | |
| InspirationTime_s | |
| OxygenInletVolumeFraction | |
| TotalBreathingCycleTime_s | |
Detailed Description
Amount of oxygen in the bottle.