What’s New in the Pulse Physiology Engine 4.4.0
×
ConfigurationData_EnergyConfigurationData

Modules

 BodySpecificHeat
 Specific heat of body tissue, used for the core and skin thermal capacitances.
 
 ThermoneutralCoreTemperatureLow
 Lower edge of the thermoneutral band. Shivering ramps up below it; it is a set point, not a hypothermia limit.
 
 ThermoneutralCoreTemperatureHigh
 Upper edge of the thermoneutral band. Sweating ramps up above it; it is a set point, not a hyperthermia limit.
 
 DeltaCoreTemperatureLow
 Width of the shivering proportional band: the drop below ThermoneutralCoreTemperatureLow over which metabolic rate ramps from basal to the summit metabolism.
 
 EnergyPerATP
 Energy released per mole of ATP consumed.
 
 SweatHeatTransfer
 Gain of the sweating controller: evaporative power commanded per degree of core temperature above ThermoneutralCoreTemperatureHigh. Divided by VaporizationEnergy to give a sweat rate.
 
 VaporizationEnergy
 Latent heat of vaporization of water at skin temperature. Converts sweat mass to evaporative cooling in both the energy and environment models.
 
 MaximumSweatRate
 Ceiling on the whole body sweat rate, where the sweat glands saturate.
 