ExtracorporealMembraneOxygenationDeviceSettingsData
Modules | |
| InletLocation | |
| Drainage location. eExtracorporealMembraneOxygenationDeviceCannulationLocation. | |
| OutletLocation | |
| Return location. eExtracorporealMembraneOxygenationDeviceCannulationLocation. | |
| Pump | |
| Return location. eExtracorporealMembraneOxygenationDeviceCannulationLocation. | |
| PumpFlow | |
| Total blood flow through the device. | |
| Rates | |
| Total blood flow through the device. | |
| CarbonDioxideRate | |
| Oxygenator rate of CO2 removal. | |
| OxygenRate | |
| Oxygenator rate of O2 delivery. | |
| Diffusion | |
| Oxygenator rate of O2 delivery. | |
| CarbonDioxideMembraneDiffusingCapacity | |
| Membrane diffusing capacity for carbon dioxide removal. | |
| FractionOfSweepGasOxygen | |
| Fraction of oxygen in the sweep gas. | |
| OxygenMembraneDiffusingCapacity | |
| Membrane diffusing capacity for oxygen delivery. | |
| SweepGasPressure | |
| Regulated gauge pressure of the sweep gas at the oxygenator inlet (distinct from upstream supply pressure). | |
| SweepGasFlow | |
| Flow rate of the sweep gas through the oxygenator. | |
| Administration | |
| Flow rate of the sweep gas through the oxygenator. | |
| BagCompound | |
| Fluid administration substance concentration in the bag. | |
| BagVolume | |
| Fluid administration volume of the compound bag. | |
| InfuserRate | |
| Fluid administration flow rate of the infuser. | |
| Volumes | |
| Fluid administration flow rate of the infuser. | |
| DrainageCannulaVolume | |
| Volume of the drainage cannula. | |
| DrainageLimbVolume | |
| Volume of the drainage limb tubing. | |
| InfuserVolume | |
| Volume of the infuser. | |
| InletProbeVolume | |
| Volume of the inlet probe. | |
| OutletProbeVolume | |
| Volume of the outlet probe. | |
| OxygenatorLiquidVolume | |
| Volume of the liquid in the oxygenator. | |
| PumpVolume | |
| Volume of the pump. | |
| ReturnCannulaVolume | |
| Volume of the return cannula. | |
| ReturnLimbVolume | |
| Volume of the return limb tubing. | |
| OxygenatorGasVolume | |
| Volume of the gas in the oxygenator. | |
| Resistances | |
| Volume of the gas in the oxygenator. | |
| DrainageCannulaResistance | |
| Resistance of the drainage cannula. | |
| DrainageLimbResistance | |
| Resistance of the drainage limb tubing. | |
| OxygenatorResistance | |
| Resistance of the oxygenator. | |
| ReturnCannulaResistance | |
| Resistance of the return cannula. | |
| ReturnLimbResistance | |
| Resistance of the return limb tubing. | |