MechanicalVentilatorSettingsData

Modules

 Connection
 eSwitchTable
 
 ConnectionVolume
 Dead space volume of the connection (i.e., mask/tube).
 
 Compliance
 Total compliance of the entire mechanical ventilator circuit.
 
 DriverDampingParameter
 Fractional change parameter to prevent abrupt changes to the driver.
 
 ExpiratoryBaseline
 Fractional change parameter to prevent abrupt changes to the driver.
 
 PositiveEndExpiratoryPressure
 Extrinsic pressure above atmosphere at the end of exhalation.
 
 FunctionalResidualCapacity
 Total lung volume at the end of exhalation.
 
 ExpirationCycle
 Total lung volume at the end of exhalation.
 
 ExpirationCycleFlow
 Ventilator sensor flow value to trigger expiration phase.
 
 ExpirationCyclePressure
 Ventilator sensor pressure value to trigger expiration phase.
 
 ExpirationCycleTime
 Total length of inspiration phase to trigger expiration phase.
 
 ExpirationCycleVolume
 Ventilator sensor volume change (i.e., tidal volume) to trigger expiration phase.
 
 ExpirationCycleRespiratoryModel
 Trigger expiration phase from respiratory model event.
 
 ExpirationLimbVolume
 Dead space volume of the expiratory limb.
 
 ExpirationTubeResistance
 Total resistance of expiratory limb tubing.
 
 ExpirationValveResistance
 Total resistance of expiratory valves.
 
 ExpirationValveVolume
 Dead space volume of the expiratory valve.
 
 ExpirationWaveform
 MechanicalVentilatorData_eDriverWaveformTable
 
 ExpirationWaveformPeriod
 Time to reach minimum value.
 
 InspirationLimit
 Time to reach minimum value.
 
 InspirationLimitFlow
 Ventilator sensor flow cutoff/maximum.
 
 InspirationLimitPressure
 Ventilator sensor pressure cutoff/maximum.
 
 InspirationLimitVolume
 Total lung volume cutoff/maximum.
 
 InspirationPauseTime
 Time of plateau (i.e., constant driver pressure) between inspiration and expiration.
 
 InspiratoryTarget
 Time of plateau (i.e., constant driver pressure) between inspiration and expiration.
 
 InspirationTargetFlow
 Air flow at end of inhalation.
 
 PeakInspiratoryPressure
 Extrinsic pressure above atmosphere at the end of inhalation.
 
 InspirationMachineTrigger
 Extrinsic pressure above atmosphere at the end of inhalation.
 
 InspirationMachineTriggerTime
 Total length of expiration phase to trigger inspiration phase.
 
 InspirationPatientTrigger
 Total length of expiration phase to trigger inspiration phase.
 
 InspirationPatientTriggerFlow
 Ventilator sensor volume change value to trigger inspiration phase.
 
 InspirationPatientTriggerPressure
 Ventilator sensor pressure value to trigger inspiration phase.
 
 InspirationPatientTriggerRespiratoryModel
 Trigger inspiration phase from respiratory model event.
 
 InspirationLimbVolume
 Dead space volume of the inspiratory limb.
 
 InspirationTubeResistance
 Total resistance of inspiratory limb tubing.
 
 InspirationValveResistance
 Total resistance of inspiratory valves.
 
 InspirationValveVolume
 Dead space volume of the inspiratory valve.
 
 InspirationWaveform
 MechanicalVentilatorData_eDriverWaveformTable
 
 InspirationWaveformPeriod
 Time to reach maximum value.
 
 ReliefValveThreshold
 Pressure at which the relief valve opens.
 
 YPieceVolume
 Dead space volume of the y-piece.
 
 FractionInspiredGas
 Break down of the gases, such as FiO2.
 
 ConcentrationInspiredAerosol
 Concentration of added aerosolized substances.
 