MechanicalVentilatorSettingsData
FiO2 fraction threshold for oxygen supply failure alarm. More...
Modules | |
| Connection | |
| eSwitchTable | |
| ConnectionVolume | |
| Dead space volume of the connection (i.e., mask/tube). | |
| Compliance | |
| Total compliance of the entire mechanical ventilator circuit. | |
| DriverDampingParameter | |
| Fractional change parameter to prevent abrupt changes to the driver. | |
| ExpiratoryBaseline | |
| Fractional change parameter to prevent abrupt changes to the driver. | |
| PositiveEndExpiratoryPressure | |
| Extrinsic pressure above atmosphere at the end of exhalation. | |
| FunctionalResidualCapacity | |
| Total lung volume at the end of exhalation. | |
| ExpirationCycle | |
| Total lung volume at the end of exhalation. | |
| ExpirationCycleFlow | |
| Ventilator sensor flow value to trigger expiration phase. | |
| ExpirationCyclePressure | |
| Ventilator sensor pressure value to trigger expiration phase. | |
| ExpirationCycleTime | |
| Total length of inspiration phase to trigger expiration phase. | |
| ExpirationCycleVolume | |
| Ventilator sensor volume change (i.e., tidal volume) to trigger expiration phase. | |
| ExpirationCycleRespiratoryModel | |
| Trigger expiration phase from respiratory model event. | |
| ExpirationLimbVolume | |
| Dead space volume of the expiratory limb. | |
| ExpirationTubeResistance | |
| Total resistance of expiratory limb tubing. | |
| ExpirationValveResistance | |
| Total resistance of expiratory valves. | |
| ExpirationValveVolume | |
| Dead space volume of the expiratory valve. | |
| ExpirationWaveform | |
| MechanicalVentilatorData_eDriverWaveformTable | |
| ExpirationWaveformPeriod | |
| Time to reach minimum value. | |
| InspirationLimit | |
| Time to reach minimum value. | |
| InspirationLimitFlow | |
| Ventilator sensor flow cutoff/maximum. | |
| InspirationLimitPressure | |
| Ventilator sensor pressure cutoff/maximum. | |
| InspirationLimitVolume | |
| Total lung volume cutoff/maximum. | |
| InspirationPauseTime | |
| Time of plateau (i.e., constant driver pressure) between inspiration and expiration. | |
| InspiratoryTarget | |
| Time of plateau (i.e., constant driver pressure) between inspiration and expiration. | |
| InspirationTargetFlow | |
| Air flow at end of inhalation. | |
| PeakInspiratoryPressure | |
| Extrinsic pressure above atmosphere at the end of inhalation. | |
| InspirationMachineTrigger | |
| Extrinsic pressure above atmosphere at the end of inhalation. | |
| InspirationMachineTriggerTime | |
| Total length of expiration phase to trigger inspiration phase. | |
| InspirationPatientTrigger | |
| Total length of expiration phase to trigger inspiration phase. | |
| InspirationPatientTriggerFlow | |
| Ventilator sensor volume change value to trigger inspiration phase. | |
| InspirationPatientTriggerPressure | |
| Ventilator sensor pressure value to trigger inspiration phase. | |
| InspirationPatientTriggerRespiratoryModel | |
| Trigger inspiration phase from respiratory model event. | |
| InspirationLimbVolume | |
| Dead space volume of the inspiratory limb. | |
| InspirationTubeResistance | |
| Total resistance of inspiratory limb tubing. | |
| InspirationValveResistance | |
| Total resistance of inspiratory valves. | |
| InspirationValveVolume | |
| Dead space volume of the inspiratory valve. | |
| InspirationWaveform | |
| MechanicalVentilatorData_eDriverWaveformTable | |
| InspirationWaveformPeriod | |
| Time to reach maximum value. | |
| ReliefValveThreshold | |
| Pressure at which the relief valve opens. | |
| YPieceVolume | |
| Dead space volume of the y-piece. | |
| Alarms | |
| Dead space volume of the y-piece. | |
| FractionInspiredGas | |
| Break down of the gases, such as FiO2. | |
| ConcentrationInspiredAerosol | |
| Concentration of added aerosolized substances. | |
Detailed Description
FiO2 fraction threshold for oxygen supply failure alarm.